Power Generation

SUPERIOR POWER GENERATION PRODUCTS, LESS DOWNTIME, EXTRA SUPPORT.

Power Generation is one of our main business line at Caraka. With over 30 years of management experience in the Power Generation supply and aftersales business, we are committed to our customers to meet their changing needs, be it meeting project specifications, budgeting for EPC proposals, and meeting the quality standards of our clients. We only supply the most reliable, value-to-cost, and quality Power Generation items to our clients and we provide complete supply packages such as Gen-Sets, Synchronizing Panels, ATS and Maintenance Contracts.

At Caraka, we believe Power Generation has to be available anytime it is needed. Reliability depends greatly on the product, so we strive to use reliable and quality component in our Generating Set with certified Cummins® Engines and Stamford® Alternators to deliver reliable, worry-free electricity supply for Users. Customers also can request auxiliaries such as ATS Panel, Synchronizing Panel, and competitive Generator Set maintenance package for complete peace of mind. We have certified and knowledgeable technicians able to support Cummins and Stamford products, alongside consumable and critical parts in stock.

 

Generating Set Rated 400V @ (50Hz/1500rpm)

Cummins x Stamford Range

Engine Type Altenator Type
Ratings
Standby Power Prime Power
kVA kVA
4B3.9-G2 PI144E 27 25
4B3.9-G2 PI144F 30 27.5
4BT3.9-G2 PI144G 33 30
4BT3.9-G2 PI144H 30 35
4BT3.9-G2 PI144J 45 40
4BTA3.9-G2 UCI224D 55 50
4BTA3.9-G2 UCI224E 65 60
4BTA3.9-G2 UCI224F 68 62
4BTA3.9-G11 UCI224F 80 72
6BT5.9-G2 UCI224G 95 85
6BT5.9-G2 UCI274C 110 100
6BTA5.9-G2 UCI274D 125 112
6BTAA5.9-G2 UCI274E 148 135
6BTAA5.9-G12 UCI274F 165 150
6CTA8.3-G2 UCI274F 175 160
6CTA8.3-G2 UCI274G 200 182
6CTAA8.3-G2 UCI274H 220 200
6LTAA8.9-G2 UCDI274K 275 250
6LTAA8.9-G3 HCI444D 288 263
6ZTAA13-G3 HCI444F 415 375
6ZTAA13-G2 HCI544C 460 438
6ZTAA13-G4 HCI544C 460 450
NT855-GA UCDI274K 275 250
NTA855-G1A HCI444D 315 275
NTA855-G1A HCI444D 315 275
NTA855-G1B HCI444ES 350 312
NTAA855-G2A HCI444E 388 350
NTA855-G4 HCI444E 388 350
NTAA855-G7 HCI444FS 415 375
NTAA855-G7A HCI444F 450 400
QSZ13-G2 HCI544C 475 450
QSZ13-G3 HCI544C 500 475
KTA19-G4 HCI544C 550 500
KTAA19-G5 HCI544D 600 550
KTA19-G8 HCI544E 650 600
KTAA19-G6A HCI544FS 688 625
QSKTAA19-G4 NR2 HCI544F 715 650
KT38-GA LVI634B 800 725
KTA38-G2 LVI634B 825 750
KTA38-G2B HCI634G 880 800
KTA38-G2A HCI634H 1000 900
KTA38-G5 HCI634J 1100 1000
KTA38-G9 HCI634K 1250 1125
QSK38-G5 LVI634G 1375 1250
KTA50-G3 LVI634G 1375 1250
KTA50-G8 PI734C 1540 1400
KTA50-GS8 PI734C 1650 1500

Notes:

  1. Gross engine performance is in accordance with ISO3046 (BS5514 & DIN 6271 standards are based on ISO 3046) or GB/T 18297.
  2. The quoted typical output ratings are not guaranteed Standby kWm (net) and kWe(kVA) figures do not include 1% reduction for governing.
    Refer AEB 10.47 for Cummins preferred method of power output calculation.
  3. Quoted gross standby ratings relate to nominal power output capability of the engine. These are certified +/- 5%.
  4. For definition of power output refer to Cummins power rating application guidelines (AEB 26.02) which are based on ISO8528.
  5. kVA figures are calculated using a 0.8 power factor.